Which pipe should I use for central heating?

Which pipe should I use for central heating?
Copper, or a barrier-grade plastic pipe — non-barrier plastic lets oxygen into the system and corrodes it from the inside.

A sealed heating system is designed to become oxygen-depleted: once the small amount of dissolved oxygen in the fill water has reacted, corrosion effectively stops and the system can run for decades. Non-barrier plastic pipe defeats that by allowing oxygen to diffuse continuously through the pipe wall, so corrosion never stops — the result is black magnetite sludge, cold spots at the bottom of radiators, a failing pump and blocked heat exchangers. The barrier layer, usually EVOH or aluminium, is the entire point of heating-grade plastic pipe and it is not a marketing distinction. Add an inhibitor to the system water and fit a magnetic filter, and the corrosion products that do form are captured rather than circulated.

The options, ranked

Ranked best-first for the stated job. The third column is why the others exist.
Option Good at Bad at
Copper Impermeable to oxygen, takes any system temperature, and rigid enough to hold its line neatly. Costs more and takes longer to install.
Barrier PEX or PE-RT An EVOH layer stops oxygen diffusing through the wall, which is what makes it usable in a sealed heating system. Must be the barrier grade, and it needs inserts and frequent support.
Multilayer (PE-AL-PE) pipe An aluminium core gives a total oxygen barrier and lets the pipe hold a bend like metal. Needs press or compression fittings and the right tooling.
Non-barrier plastic pipe Cheap, and fine for cold water and irrigation. Oxygen diffuses straight through it into the heating water, rusting radiators and pump from inside.

Technique that changes the outcome

  1. Use only barrier-grade pipe, and check the printing on the pipe itself
  2. Fit inserts in every plastic joint and support the pipe frequently
  3. Flush the system and add a corrosion inhibitor after any work
  4. Fit a magnetic filter on the return before the boiler

What goes wrong

  • Non-barrier pipe anywhere in a heating circuit
  • Mixing metals badly — an aluminium radiator on an unsuitable inhibitor corrodes quickly
  • Skipping the inhibitor after draining the system, which is the commonest cause of sludge

Compiled practical guidance rather than a published standard. Product formulations vary by brand and market, so read the label — and where the work is structural, electrical or gas, the regulations that apply where you are govern rather than anything here.

Other pipe questions

For Use
Hot and cold water Copper or PEX for most installations — PEX is faster and more freeze-tolerant, copper is more robust and takes heat without question.
Waste and drainage Solvent-weld or push-fit PVC-u or polypropylene, at the right diameter and fall — and ABS and PVC cements are not interchangeable.
Boiler condensate Plastic, never copper, at a generous diameter with continuous fall — and insulate any external run, because frozen condensate is the classic winter breakdown.
Gas Steel, copper of the right grade, or yellow MDPE underground — and in most jurisdictions only a registered installer may do the work.
An underground water supply Blue MDPE for potable water, in one continuous length at the required depth, with no joints under a building.
Compressed air Copper, steel, stainless or a purpose-rated aluminium or HDPE air system — never PVC, which fails explosively.
Irrigation Low-density polyethylene tubing with barbed fittings for drip lines, and PVC or MDPE for buried mains.

Common questions

Which pipe should I use for central heating?
Copper, or a barrier-grade plastic pipe — non-barrier plastic lets oxygen into the system and corrodes it from the inside.
What should I avoid?
Non-barrier pipe anywhere in a heating circuit Mixing metals badly — an aluminium radiator on an unsuitable inhibitor corrodes quickly Skipping the inhibitor after draining the system, which is the commonest cause of sludge